Paths, 24 steps in six parts after an overview, none written yet
GBM segmentation
The glomerular basement membrane, part of the kidney’s filter, is imaged in 3D in expanded tissue, but the images are far coarser in depth than across. This study segments it without annotating the missing depth and measures its thickness on the GPU. This path teaches what is needed to follow it: the biology and the images, the networks, the two ideas that supply the missing axial information, and how thickness is measured and validated.
none read yet
No step is written yet.Map
Confocal images of cleared, expanded tissue resolve the membrane finely across each slice but sample it coarsely from slice to slice, so in depth it can look broken. The usual remedy, upsampling the volume and annotating it densely, costs too much labelling. The study trains on the volumes as they were acquired: random rotations of the training patches lend the fine lateral detail to the depth axis, and a continuity loss keeps neighbouring slices consistent. The predictions of overlapping patches are joined by a Gaussian consensus, and the membrane’s thickness is measured by casting rays on the GPU, corrected for the microscope’s blur. The path starts with the study in one page, then the biology and the images, the networks, the method, the measurement and the results.
The steps
The study in brief
Step 1
-
GBM segmentation in one pageUnder construction
Part 1 The biology
Steps 2 to 3
-
The kidney’s filtration barrierUnder construction
The three layers that filter the blood, the basement membrane in the middle.
Crossing: also step 2 of AMAP-APP
-
The glomerular basement membraneUnder construction
The membrane the study segments: its undulating shape, and how it thickens and grows irregular in disease.
Part 2 The images
Steps 4 to 7
-
Fluorescence microscopyUnder construction
How a stain makes the membrane visible to a confocal microscope.
Crossing: also step 4 of AMAP-APP
-
Super-resolution microscopyUnder construction
Expansion microscopy: swelling the tissue so that a standard microscope resolves nanoscale structure.
Crossing: also step 5 of AMAP-APP
-
Anisotropic volumesUnder construction
Volumes sampled coarser in depth than across, and why a structure can look broken along the depth axis.
-
The point spread functionUnder construction
The blur a microscope adds to every point, which makes a membrane look thicker than it is.
Part 3 The networks
Steps 8 to 12
-
ConvolutionUnder construction
The operation convolutional networks are built from, here in three dimensions.
Crossing: also step 6 of AMAP-APP
-
Vision transformersUnder construction
Transformers applied to images, cut into patches.
-
Swin transformers and SwinUNETRUnder construction
SwinUNETR, the transformer backbone the study adapts: attention in shifted windows, in a U-shaped network.
-
Image segmentationUnder construction
A label for every voxel: membrane or not.
Crossing: also step 9 of AMAP-APP
Part 4 The method
Steps 13 to 18
-
Data augmentationUnder construction
Changing the training data on the fly so the network sees more than was annotated.
-
Rotation as axial supervisionUnder construction
Random rotations that turn the fine lateral detail into supervision for the coarse depth axis.
-
Loss functionsUnder construction
What a network is trained to lower, and how a loss can encode a property of the result.
-
The z-continuity lossUnder construction
The loss that keeps neighbouring slices consistent, and the terracing artefact it suppresses.
-
Tiled inferenceUnder construction
Large volumes processed in overlapping patches.
Crossing: also step 10 of AMAP-APP
-
Gaussian consensus of patchesUnder construction
Joining the overlapping predictions with Gaussian weights.
Part 5 Measuring the membrane
Steps 19 to 21
-
Computing on the GPUUnder construction
Thousands of small computations in parallel, as the measurement needs.
-
Ray–surface intersectionUnder construction
Where a ray meets a surface: the geometry behind measuring thickness.
-
Membrane thickness on the GPUUnder construction
Thickness measured by rays through the reconstructed surface, corrected for the point spread function.
Part 6 The results
Steps 22 to 24
-
Dice and IoUUnder construction
The overlap scores that compare a segmentation with an expert’s.
-
Cross-validationUnder construction
Cross-validation: how the accuracy was estimated on volumes the model did not train on.
-
Accuracy, continuity and diseaseUnder construction
Accuracy at the level of expert agreement, smoother reconstructions, and the thickening of the membrane in a diseased kidney.
At the end of the path
At the end of the path you can explain why anisotropic volumes break a membrane along the depth axis, how rotation and a continuity loss supply the missing information without new annotations, and how the membrane’s thickness is measured and corrected for the microscope.
Now see the researchGBM segmentation: the code (the dataset is on Zenodo, 10.5281/zenodo.21793752)
What you mark as read is kept in this browser only, never sent.